If your Autel IM508 or IM608 key programmer is experiencing charging issues or failing to hold a charge, consider the following solutions:
Solution 1: Direct Power Connection
Procedure: Carefully dismantle the device’s display to access the internal wiring. Strip the red and black wires and connect them directly to a power source for approximately 3 hours.
Outcome: This method has been reported to restore the battery’s ability to charge and hold power effectively.
Solution 2: Battery Replacement
Procedure: If the direct power connection method doesn’t solve the problem, replacing the battery is a straightforward solution.
Autel IM608 IM608 Pro replacement battery
Tech support:
Email: Sales@UOBDII.com
WhatsApp: +86-13995696053
Skype: UOBD2.COM